  • Cinere One Commercial(COC) Blok KA18 Jl. Merawan Pangkalan Jati - Cinere, Depok 16513

WELL GAS METER (WGM)

Wet Gas Meter is a state-of-the-art technology for inline measurement of wet gas flow. The meter allows accurate measurement of liquid (water/condensate) content in the gas and individual flow rate of gas and liquid,with a very compact mechanical solution. Depending upon the.

Specifications

Dimension 1.5 ~ 16 inch
Operating Pressure 0 ~ 35 MPa
Operating Temperature -50 to 150 °C
Operating Range 90 ~ 100% (GVF), 0 ~ 0.3 (LM)
Flange Connection ASME, API, Hub
Wetted Parts Materials SS, DSS, CS, Inconel, Alloy
Power Supply 24VDC or 110/220VAC
Power Consumption < 50W
Output Interface RS232/485
Communication Protocol Modbus RTU, ASCII, TCP

Introduction

Wet Gas Meter is a state-of-the-art technology for inline measurement of wet gas flow. The meter allows accurate measurement of liquid (water/condensate) content in the gas and individual flow rate of gas and liquid, with a very compact mechanical solution. Depending upon the client's requirement, the meter can either be a spool piece or skid mounted design.


Feature

  • 1. Compact, lightweight, and modular
  • 2. Non-Intrusive
  • 3. No moving parts, low maintenance requirements
  • 4. Wide operational range
  • 5. Remote operation and self-verification
  • 6. Remote operation and data acquisition
  • 7. Unique in-line wet gas model
  • 8. Low-pressure loss
  • 9. Low power consumption

Oil/Gas/Water Three-phase Flow Measurement System

Oil/Gas/Water Three-phase Flow Measurement System SITAN YQF-100 Oil/Gas/Water three-phase flow measurement system dynamically monitors the proportion of liquid, oil and gas. The liquid is separated from the gas with the advanced columnar swirl gas-liquid separation and gravity settling...

Specifications

Liquid Measurement Error ≤±2% is 5
Water Holdup Error ≤±3%
Gas Measurement Accuracy 1.5%
Working Pressure 4 MPa
Pressure Loss ≤ 0.1 MPa (15 PSI)
Medium Temperature 5 °C ~ 80 °C
Environment Temperature -40 °C ~ 85 °C
Explosion Level ExdⅡCT4 ∼ T6 / ExibⅡCT4 ∼ T6 / ExdⅡBT4
Protection Class IP65 ~ IP67

Specifications

Liquid Measurement Error ≤±2% is 5
Water Holdup Error ≤±3%
Gas Measurement Accuracy 1.5%
Working Pressure 4 MPa
Pressure Loss ≤ 0.1 MPa (15 PSI)
Medium Temperature 5 °C ~ 80 °C
Environment Temperature -40 °C ~ 85 °C
Explosion Level ExdⅡCT4 ∼ T6 / ExibⅡCT4 ∼ T6 / ExdⅡBT4
Protection Class IP65 ~ IP67

Introduction


Oil/Gas/Water Three-phase Flow Measurement System

SITAN YQF-100 Oil/Gas/Water three-phase flow measurement system dynamically monitors the proportion of liquid, oil, and gas. The liquid is separated from the gas with the advanced columnar swirl gas-liquid separation and gravity settling technology and measured accurately with the Coriolis mass flow meter. Gas is measured by the gas flow meter. The mass measuring is not affected by the medium character, complying with oil field conditions. Adopting the density method and mathematical models designed for density method-related water ratio measuring, the system performs the measuring of the water(oil) proportion as well as the measuring and displaying of the total mass, flow rate, and density of the oil/water/gas mixture. SITAN YQF-100 Oil/Gas/Water three-phase flow measurement system improves the measurement technology of oil production and provides reliable data for production strategies.


Feature

  • 1. High accuracy and real-time online measurement.
  • 2. High measurement accuracy, real-time online measurement of three-phase flow curves of oil, gas, and water.
  • 3. Simple operation, easy movement, installation, and maintenance.
  • 4. Small volume and lightweight.
  • 5. High reliability and less maintenance.
  • 6. Wide availability and range.